Five sample buildings. Twenty-four months of monitoring

​

Between May 2024 and May 2026, the validation protocol was applied to five sample buildings. Masonry was subjected to non-invasive dielectric measurements using a Trotec instrument, expressed in Digit, through scheduled readings at predefined points, supplemented by thermographic analysis and mapping.

Over the 24-month period, all monitored cases showed a progressive reduction in measured values. The assessment is therefore based on the overall trend of measurements over time rather than on any single reading.

ChatGPT Image 7 set 2026, 16_11_16.png

THERMOGRAPHIC VERIFICATION​

​

A comparison of the same wall shows a change in the surface temperature differential from ΔT 1.7 K, measured in May 2024, to ΔT 0.9 K, measured in November 2025.

The reduction is consistent with a more uniform surface temperature distribution.

Thermography provides complementary evidence and is not a direct measurement of the water content in the masonry.